Project Description
120℃ Water Temperature Control Unit
— LWM Series
About the unit
The water temperature controller LWM series is designed to work with a wide range of high temperature application up to 120 ºC, which are used for controlled heating of products, mechanisms and factory machinery in a wide range of industries, including chemical reaction and casting industry etc.
High temperature water from the mould is returned to the unit and pressurized by high-pressure pump, sent to the heating tank and finally to the mould with a constant temperature.
Main specification
Temperature rage: Inlet water temp +15℃~120℃
Heat transfer medium: Water
Heater power : 6~24 kw
Pump: 0.5 ~ 3 HP
Main application: Injection mould | Extrusion | Roller
Feature
- High precision ±1°C controlled
- Return water temperature display
- Stainless steel pipeline reduce resistance and rusty
- Omron, Fuji, LG, Siemens, Schneider brand electrical equipment
- Microcomputer control system
- Automatic exhaust function for start-up
- Heating power switching function
- Improved safe protection and fault indication, easy operation for maintenance
- Isolated type electric control box prolong the service life of electric appliance
- By-pass pressure relief loop
Available option
- Power supply : 220~480V, 50/60Hz
- Instant cooling and shut-down function
- Multi-point temperature control unit can be customized
- RS 485 communication function for remote control
- PLC control system and touch screen
Function security
- Abnormal temperature protection
- Reverse phase protection of power supply
- Short circuit protection
- Pump overload protection
- Abnormal heating protection
- Pipe clogging protection
- Abnormal pressure stops heating protection
- Automatic exhaust protection
Application
- Injection mould
- Extrusion
- Roller temperature control
- Printing equipment
Specification
Item | LWM-05 | LWM-10 | LWM-20 | LWM-30 | LWMD-05 | LWMD-10 | ||
---|---|---|---|---|---|---|---|---|
Temp. control range | Inlet water temperature+15 ℃~ 120 ℃ | |||||||
Temp. control accuracy | PID±1 ℃ | |||||||
Power supply | AC3Ф380V 50HZ (220~480V, 50/60Hz for option) | |||||||
Heat transfer medium | Water | |||||||
Cooling method | Direct cooling ( Indirect cooling for option ) | |||||||
Heating power | KW | 6 | 9 | 9/12 | 18/24 | 6+6 | 9+9 | |
Pump horsepower | KW | 0.5 | 1 | 2 | 3 | 0.5+0.5 | 1+1 | |
Flow rate | L / Min | 95 | 165 | 236 | 315 | 95+95 | 165+165 | |
Pump pressure | Bar | 2 | 2.2 | 2.4 | 3 | 2+2 | 2.2+2.2 | |
Max. power consumption | KW | 7 | 10 | 11/14 | 21/27 | 13 | 20 | |
Cooling water pipe | Inch | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | |
Circulation pipe | Inch | 3/8×2 | 3/8×4 | 1 | 1 | (3/8×2)×2 | (3/8×4)×2 | |
Size | Depth | mm | 650 | 625 | 625 | 755 | 625 | 625 |
Width | mm | 280 | 325 | 325 | 360 | 650 | 650 | |
Height | mm | 520 | 650 | 650 | 855 | 650 | 650 | |
Weight | KG | 62 | 68 | 75 | 90 | 120 | 130 |
Note: The specification is subject to change due to product improvement without prior notice.